The Infinity Moog Pump is a portable, reliable enteral feeding system designed for precise nutrition delivery. Part of the Zevex Infinity series, it offers advanced features for patient care.
1.1 Overview of the Infinity Moog Pump
The Infinity Moog Pump, part of the Zevex Infinity series, is a portable enteral feeding system designed for precise nutrition delivery. It utilizes rotary peristaltic technology, ensuring accurate flow rates and reliability. Compact and lightweight, the pump is ideal for mobile use, offering a user-friendly interface for easy operation. Its design supports continuous or bolus feeding, making it suitable for various clinical and home care settings. The pump’s durability and advanced features enhance patient care and mobility.
1.2 Importance of the Manual for Users
The manual is essential for safe and effective use of the Infinity Moog Pump. It provides detailed instructions for setup, operation, and troubleshooting, ensuring users understand safety measures and optimal functionality. Proper adherence prevents errors, enhances patient care, and maintains warranty validity. The guide is crucial for both healthcare professionals and caregivers, offering clear steps to address common issues and ensure seamless nutrition delivery.

Key Features and Benefits
The Infinity Moog Pump offers portability, precision, and reliability, making it ideal for continuous nutrition delivery. Its compact design ensures ease of use and mobility for patients.
2.1 Design and Portability
The Infinity Moog Pump features a compact, lightweight design, making it highly portable for patients. Its intuitive interface and durable construction ensure ease of use and reliability. The pump’s small size allows for convenient transport, while its battery life supports extended use without recharging. This portability enhances patient mobility, making it ideal for both home and clinical settings.
2.2 Precision and Reliability in Nutrition Delivery
The Infinity Moog Pump ensures accurate and consistent nutrition delivery through its advanced rotary peristaltic technology. It reliably manages feeding schedules and volumes, minimizing errors. The pump detects issues like air in tubing or occlusions, alerting users promptly. Its precise flow control and alarm systems enhance safety, making it a trusted solution for enteral feeding. Regular maintenance, as outlined in the manual, further ensures optimal performance and reliability.
Setup and Initialization
Unbox and inspect the pump, ensuring all components are included. Follow the step-by-step guide to initialize the device, preparing it for safe and effective operation.
3.1 Unboxing and Initial Inspection
Begin by carefully unboxing the Infinity Moog Pump and inspecting for any visible damage. Ensure all components, including tubing, bags, and accessories, are included. Clean the pressure sensor with a soft cloth or cotton swab to ensure accuracy. Verify the pump’s serial number matches the manual. Check for any obstructions or kinks in the tubing, as these can affect performance. Proper inspection ensures safe and reliable operation from the start.
3.2 Step-by-Step Setup Process
Connect the tubing to the pump and feeding bag, ensuring no kinks or obstructions. Prime the tubing by filling it with formula to remove air bubbles. Load the feeding bag into the pump’s compartment, securing it firmly. Set the desired flow rate and feeding duration using the control panel. Power on the pump and verify all settings before starting. Ensure the pressure sensor is clean for accurate monitoring. Follow the manual for specific calibration steps to ensure proper function.
Operating the Pump
Power on the pump, select the desired settings, and monitor the display for accurate delivery. Ensure tubing is free from kinks and air bubbles for smooth operation.
4.1 Starting the Pump for the First Time
Begin by unboxing and inspecting the pump for damage. Prime the tubing according to the manual to ensure no air bubbles are present. Charge the battery fully before first use. Plug in the power cord and turn on the device. Follow the initial setup wizard to set time, date, and language. Load the feeding set correctly, ensuring proper alignment. Refer to the manual for specific button sequences to initiate operation safely.
4.2 Adjusting Flow Rates and Settings
Use the control panel to navigate to the settings menu. Select the desired flow rate and confirm the adjustment. Ensure the tubing is free from kinks or blockages. Monitor the display for any alarms or error messages. Adjust settings cautiously to avoid over-delivery or under-delivery of nutrition. Refer to the manual for specific button sequences and guidelines to ensure accurate adjustments and maintain safe operation.
Troubleshooting Common Issues
Identify alarms and error messages promptly. Check for tubing obstructions, air bubbles, or empty delivery sets. Refer to the troubleshooting guide for step-by-step solutions and maintenance tips.
5.1 Understanding Alarms and Error Messages
The Infinity Moog Pump features alarms to alert users of issues like downstream occlusions, air in tubing, or empty delivery sets. Error messages such as “NO FOOD” indicate the need to re-prime the pump. Always check for blockages, kinks, or air bubbles. Refer to the troubleshooting guide for specific solutions. Understanding these alerts ensures timely resolution and continuous operation. Regularly review the manual for a comprehensive list of codes and corrective actions.
5.2 Resolving Occlusions in the Tubing
To resolve occlusions, inspect the tubing for kinks or blockages. Gently straighten kinked sections and ensure no obstructions are present. If an issue persists, re-prime the pump according to the manual. Clean the pressure sensor area with a soft cloth or damp sponge. Avoid aggressive mixing of formula to prevent clogs. Regularly check for air in the tubing and address it promptly to maintain smooth operation and prevent alarms. Always refer to the troubleshooting guide for detailed steps.
5.3 Addressing Air in the Tubing
If air is detected in the tubing, stop the pump immediately. Re-prime the tubing by flushing it with water or the prescribed formula. Ensure the delivery set is properly connected and free from kinks. Check for any loose connections or cracks in the tubing. If air persists, consult the troubleshooting guide or contact Moog Customer Support for assistance. Regular inspection can help prevent air-related issues and maintain smooth operation.

Maintenance and Cleaning
Regularly clean the pump with a soft cloth or damp sponge. Avoid harsh chemicals. Inspect tubing for kinks or blockages and replace as needed to ensure optimal performance.
6.1 Cleaning the Pump and Accessories
Regular cleaning is essential for maintaining the pump’s functionality. Use a soft cloth, cotton swab, or damp sponge to wipe down the exterior and internal components. Avoid harsh chemicals or abrasive materials that may damage surfaces. Inspect tubing and accessories for obstructions or kinks, and clean or replace them as needed. For thorough cleaning, wash the pump under running water, ensuring all parts are free from residue. This helps prevent contamination and ensures reliable operation.
6.2 Regular Maintenance Checks
Perform regular maintenance checks to ensure optimal pump performance and safety. Inspect tubing for kinks or obstructions, clean the pressure sensor area with a soft cloth, and verify battery levels. Check for firmware updates and review error logs to address potential issues early. Regularly sanitize all reusable parts and ensure proper storage of accessories. Consult the manual for detailed maintenance schedules and procedures to maintain warranty compliance and device reliability.
Charging and Battery Management
Proper charging ensures optimal battery performance. Use the original charger to avoid damage. Avoid overcharging and check battery levels regularly for uninterrupted operation.
7.1 Best Practices for Battery Care
For optimal battery performance, use the original charger and avoid overcharging. Clean terminals regularly with a soft cloth to prevent corrosion. Store the battery in a cool, dry place when not in use. Avoid extreme temperatures and physical stress. Charge the battery fully before extended use to ensure reliability. Proper care extends battery life and maintains the pump’s functionality.
7.2 Charging Procedures and Tips
Use the original charger to ensure safety and efficiency. Plug the pump into a power source and allow it to charge fully before first use. The indicator light will confirm charging status. Avoid overcharging, as it may reduce battery life. Store the charger in a dry place and keep it away from extreme temperatures. For optimal performance, update the pump’s firmware regularly and monitor charge levels during extended use. Always inspect the charger for damage before use and refer to the manual for detailed guidelines.
Training and Resources
Access training videos, downloadable user guides, and troubleshooting tips online. These resources help users master the Infinity Moog Pump’s operation, ensuring safe and effective use.
8.1 Available Training Videos
Training videos for the Infinity Moog Pump are accessible online, providing step-by-step guides for setup, operation, and troubleshooting. These videos cover priming the pump, adjusting flow rates, and resolving common issues like occlusions or air in tubing. They also demonstrate proper cleaning and maintenance procedures. Users can scan a QR code in the manual or visit the official website to access these resources, ensuring confident and correct pump usage.
8.2 Downloadable User Guides
The Infinity Moog Pump manual and additional guides are available for download online. These include the User Manual, Quick Start Guide, and Troubleshooting Guide. The manuals provide detailed instructions for setup, operation, and maintenance. Users can access these resources by visiting the official Moog website or scanning a QR code provided in the printed manual. These guides ensure proper usage and maintenance, helping users avoid warranty voidance by following correct procedures.
Safety Precautions
Always follow safety guidelines to prevent accidents. Ensure proper usage and avoid unauthorized modifications. Regularly inspect the pump and tubing for damage or wear. Follow manufacturer instructions to prevent malfunctions and ensure safe operation.
9.1 Essential Safety Measures
Always follow the manufacturer’s guidelines for safe operation. Ensure proper usage and avoid unauthorized modifications. Regularly inspect tubing for kinks or obstructions. Clean the pressure sensor area with a soft cloth or cotton swab. Avoid using damaged or unauthorized accessories, as this can void the warranty. Keep the pump away from extreme temperatures and moisture. Follow the manual’s instructions to prevent malfunctions and ensure safe, effective nutrition delivery.
9.2 Emergency Procedures
In case of an emergency, immediately turn off the pump and disconnect it from the power source. Check for obstructions or air in the tubing and resolve them. If the issue persists, contact Moog Customer Support at (800) 970-2337 for assistance. Do not attempt repairs yourself, as this may void the warranty. Always follow the manual’s troubleshooting guide and seek professional help if necessary to ensure safe and effective operation.

Warranty and Support
Contact Moog Customer Advocacy at (800) 970-2337 for assistance. Unauthorized modifications or improper use will void the warranty. Follow manual guidelines for support and repairs.
10.1 Contacting Customer Support
For assistance, contact Moog Customer Advocacy at (800) 970-2337. This team provides support for troubleshooting, repairs, and general inquiries. Ensure to have your pump model and serial number ready for efficient service. Additionally, refer to the Troubleshooting Guide in the manual for common issues before contacting support. Unauthorized modifications or improper use may void the warranty, so always follow official guidelines for maintenance and repairs.
10.2 Avoiding Warranty Voidance
To maintain warranty validity, avoid unauthorized modifications or repairs. Only use Moog-approved parts and follow the manual’s guidelines. Unauthorized alterations or improper maintenance may void the warranty. Ensure all repairs are performed by certified professionals. Adhere to the Infinity Moog Pump Manual instructions for proper usage and care. Non-compliance may result in warranty termination, leaving you responsible for repair costs.

Comparison of Models
The Infinity Moog Pump series includes the EnteraLite Infinity and Infinity Orange, each designed for specific patient needs. Both models offer portability and precise nutrition delivery.
11.1 EnteraLite Infinity vs. Infinity Orange
The EnteraLite Infinity and Infinity Orange are both part of the Zevex Infinity series, designed for enteral feeding. The EnteraLite Infinity is known for its portability and compact size, making it ideal for active users. The Infinity Orange, while similar, may cater to different clinical needs. Both models emphasize precision and reliability in nutrition delivery, ensuring consistent performance for patient care.
Advanced Settings and Customization
The Infinity Moog Pump offers customizable settings for tailored nutrition delivery, including adjustable flow rates and pressure limits, ensuring personalized care for diverse patient needs.
12.1 Customizing Pump Settings
The Infinity Moog Pump allows users to customize settings for personalized nutrition delivery. Adjust flow rates, pressure limits, and delivery modes to meet specific patient needs. Advanced options enable precise control over feeding schedules and volumes. Customization should be done under professional guidance to ensure safety and effectiveness. The pump’s intuitive interface simplifies adjustments, while maintaining reliability and consistency in nutrition delivery.

Integration with Medical Devices
The Infinity Moog Pump seamlessly integrates with various medical devices and systems, ensuring compatibility and efficient patient care. It supports connectivity with EMRs and real-time monitoring systems.
13.1 Compatibility and Integration
The Infinity Moog Pump is designed to integrate seamlessly with various medical devices and systems, ensuring compatibility and efficient patient care. It supports connectivity with electronic medical records (EMRs) and real-time monitoring systems, enhancing clinical workflow. The pump’s design allows for easy integration into healthcare settings, making it a versatile solution for enteral feeding. Its compatibility with standard medical equipment ensures smooth operation in diverse clinical environments;
User Reviews and Feedback
Users praise the Infinity Moog Pump for its portability and reliability, though some note occasional issues with occlusions and alarms. Feedback highlights ease of use and durability.
14.1 Real-World Experiences and Tips
Users share positive experiences with the Infinity Moog Pump, emphasizing its portability and reliability. Some note occasional issues with occlusions and alarms. Tips include regular cleaning, checking for kinks, and ensuring proper setup. Many users appreciate the detailed manual and troubleshooting guide, while others recommend reaching out to Moog support for persistent issues. Real-world feedback highlights the pump’s durability and ease of use, making it a trusted choice for enteral feeding needs.

Accessories and Replacement Parts
Essential accessories include cleaning kits, replacement tubing, and power adapters. These ensure proper maintenance and functionality. Users can find detailed lists in the manual or through Moog support.
15.1 Essential Accessories
The Infinity Moog Pump requires specific accessories for optimal performance. These include replacement tubing, cleaning kits, and power adapters. Additional items like formula bags and connecting sets are also necessary. Users can find these in the manual or through Moog’s customer support. Regularly replacing worn or damaged parts ensures reliable operation and maintains hygiene standards. Always use genuine Moog accessories to avoid compatibility issues and warranty voidance. These items are readily available online or through authorized distributors.
15.2 Ordering Replacement Parts
To order replacement parts for the Infinity Moog Pump, contact Moog’s customer support at (800) 970-2337 or visit their official website. Genuine parts are available online or through authorized distributors. Ensure to use only approved accessories to maintain warranty validity and prevent operational issues. Refer to the manual or support portal for a list of authorized suppliers. Always verify the authenticity of parts before purchase to ensure compatibility and safety.
The Infinity Moog Pump is a reliable, portable solution for enteral feeding, offering precision and ease of use. Proper maintenance and adherence to guidelines ensure optimal performance and safety.
16.1 Summary and Encouragement for Proper Use
The Infinity Moog Pump is a cutting-edge, portable solution for enteral feeding, designed to enhance patient care with precision and reliability. By following the manual’s guidelines, users can ensure optimal performance, safety, and longevity of the device. Regular maintenance, proper troubleshooting, and adherence to safety protocols are crucial for effective use; Encourage users to utilize training resources and reach out to support for any concerns, fostering confidence and competence in operating the pump.